2.2 Visit Length
Visit lengths affect how programs are able to schedule, and thereby when they are executed. Visits of 3 orbits or fewer are easier to schedule than longer visits, and less observing time is lost in the event that an entire visit fails. In their Phase II proposals, it is recommended that proposers group observations into visits of 3 orbits or fewer to enable earlier scheduling. If at all possible, we recommend avoiding 4 orbit visits, since they are particularly difficult to schedule. As noted in the Call for Proposals, proposers must justify the use of visits longer than 6 orbits in the Description of Observations section of their Phase I proposals.
-
COS Instrument Handbook
- Acknowledgments
- Chapter 1: An Introduction to COS
-
Chapter 2: Special Considerations when Observing with COS
- • 2.1 COS FUV Detector Lifetime Positions
- • 2.2 Visit Length
- • 2.3 Central Wavelength Settings Added in Cycle 26
- • 2.4 ORIENT constraints for Extended Sources
- • 2.5 COS Observations Below 1150 Angstroms: Resolution and Wavelength Calibration Issues
- • 2.6 Time-Dependent Sensitivity Changes
- • 2.7 Spectroscopic Use of the Bright Object Aperture
- • 2.8 Non-Optimal Observing Scenarios
- • 2.9 NUV Spectroscopic Acquisitions
- • 2.10 SNAP, TOO, and Unpredictable Source Programs with COS
- • 2.11 Choosing between COS and STIS
- Chapter 3: Description and Performance of the COS Optics
- Chapter 4: Description and Performance of the COS Detectors
-
Chapter 5: Spectroscopy with COS
- • 5.1 The Capabilities of COS
- • 5.2 TIME-TAG vs. ACCUM Mode
- • 5.3 Valid Exposure Times
- • 5.4 Estimating the BUFFER-TIME in TIME-TAG Mode
- • 5.5 Spanning the Gap with Multiple CENWAVE Settings
- • 5.6 FUV Single-Segment Observations
- • 5.7 Internal Wavelength Calibration Exposures
- • 5.8 Fixed-Pattern Noise
- • 5.9 COS Spectroscopy of Extended Sources
- • 5.10 Wavelength Settings and Ranges
- • 5.11 Spectroscopy with Available but Unsupported Settings
- Chapter 6: Imaging with COS
- Chapter 7: Exposure-Time Calculator - ETC
-
Chapter 8: Target Acquisitions
- • 8.1 Introduction
- • 8.2 Target Acquisition Overview
- • 8.3 ACQ SEARCH Acquisition Mode
- • 8.4 ACQ IMAGE Acquisition Mode
- • 8.5 ACQ PEAKXD Acquisition Mode
- • 8.6 ACQ PEAKD Acquisition Mode
- • 8.7 Exposure Times
- • 8.8 Centering Accuracy and Data Quality
- • 8.9 Recommended Parameters for all COS TA Modes
- • 8.10 Special Cases
- Chapter 9: Scheduling Observations
- Chapter 10: Bright-Object Protection
- Chapter 11: Data Products and Data Reduction
-
Chapter 12: The COS Calibration Program
- • 12.1 Introduction
- • 12.2 Ground Testing and Calibration
- • 12.3 SMOV4 Testing and Calibration
- • 12.4 COS Monitoring Programs
- • 12.5 Cycle 17 Calibration Program
- • 12.6 Cycle 18 Calibration Program
- • 12.7 Cycle 19 Calibration Program
- • 12.8 Cycle 20 Calibration Program
- • 12.9 Cycle 21 Calibration Program
- • 12.10 Cycle 22 Calibration Program
- • 12.11 Cycle 23 Calibration Program
- • 12.12 Cycle 24 Calibration Program
- • 12.13 Cycle 25 Calibration Program
- • 12.14 Cycle 26 Calibration Program
- • 12.15 Cycle 27 Calibration Program
- • 12.16 Cycle 28 Calibration Program
- • 12.17 Cycle 29 Calibration Program
- Chapter 13: Spectroscopic Reference Material
- • Glossary