Echelle Grating E230H

Description

The E230H grating is used with the NUV-MAMA and provides echelle spectra at a resolving power of ~114,0001 from 1626 to 3159 Å.

Special Considerations

A single E230H echellogram covers ~267 Å, over ~20–70 orders. The orders are spaced by only ~12.7 pixels (0.37 arcseconds) at 1650 Å and 47.2 pixels (~1.38 arcseconds) at 3100 Å. The grating must be scanned, with exposures taken at six distinct settings to cover the full spectral range of the grating.


Grating

Spectral Range

Average
Dispersion
(Å per Pixel)

Dispersion, Cross Dispersion
Plate Scale
(arcsec/pixel)

Tilts

Central
Wavelengths

Complete

Per Tilt

E230H

1626–3159

∼267

λ/228,000

0.047,0.029

Prime

1763, 2013, 2263,
2513, 2762, 3012


 

 

 

 

 

Secondary

1813, 1863, 1913,
1963, 2063, 2113,
2163, 2213, 2313,
2363, 2413, 2463,
2563, 2613, 2663,
2713, 2812, 2862,
2912, 2962

Figure 13.50: Wavelength Ranges for the E230H Grating Setting.


E230H Sensitivities


Table 13.14: E230H Sensitivities & Throughputs for a Point Source.

λ

Sensitivity

% Throughput

1700

3.1E10

0.1

1800

5.6E10

0.2

1900

7.8E10

0.2

2000

1.0E11

0.3

2100

1.4E11

0.4

2200

1.7E11

0.5

2300

2.0E11

0.5

2400

2.1E11

0.5

2500

2.2E11

0.5

2600

2.4E11

0.5

2700

2.3E11

0.5

2800

2.2E11

0.4

2900

1.9E11

0.4

3000

1.4E11

0.2

3100

8.1E10

0.1

Figure 13.51: E230H Point Source (left axis), and Diffuse Source (right axis) Sensitivities.


Throughput curve traces the peaks of the blaze function for each order.

Note:

Point source sensitivity assumes full transmission (zero slit losses). Diffuse source sensitivity assumes a 0.1" wide slit. To convert point source sensitivities to diffuse source sensitivities multiply the point source values by the grating spatial (cross dispersion) plate scale in units of arcseconds per pixel and by the width of the desired slit in units of arcseconds.

E230H Signal-to-Noise

Note:

The top axis displays constant Fλ values corresponding to the STMAG units (V+STMAGλ) on the bottom axis. Recall that STMAG=0 is equivalent to Fλ = 3.63E–9 erg/cm2/s/Å. The curves are labeled with exposure times in seconds.

Figure 13.52: Diffuse Source Signal-to-Noise as a Function of STMAG for E230H.


Figure 13.53: Point Source Signal-to-Noise as a Function of STMAG for E230H.




1 R ~ 200,000 possible with the 0.1X0.03 aperture; see Section 12.6.