E.11 The Cycle 24 Calibration Plan

The Cycle 24 calibration plan was executed from November 2016 through October 2017. The individual programs are listed in Table E.12 and are described in more detail on the WFC3 Calibration Plan webpage. In the Cycle 24 Calibration section, a similar table contains direct links to the Phase II programs and observation dates. This information may alternately be accessed via the HST Program Information webpage by entering the Proposal ID.

The WFC3 Cycle 24 section also links to a PDF presentation summarizing WFC3 usage and comparing the Cycle 24 plan with the prior cycle. This document contains more details on the calibration justification and in many cases includes supporting figures with the latest results from regular monitoring.

The Cycle 24 calibration plan was designed to:

  • maintain and update the standard reference files (biases, darks, linearity, CTE traps, UVIS anomalous QE pixels, post-flash)
  • monitor the health of the instrument (throughput, gain, hysteresis, bad/hot pixels, sink pixels, CTE decline, stability of the post-flash LED, filter transmission, wavelength and flux stability of grisms, number of IR blobs, state of the CSM)
  • test the precision of the IR count rate non-linearity correction for faint targets and determine whether a wavelength-dependent correction is required
  • improve the precision of the UVIS contamination monitor by making use of spatially scanned observations of photometric standards
  • re-evaluate the 2013 UVIS pixel-based CTE model and verify that the recommended post-flash level has not changed

The results of these calibration programs will be documented in Instrument Science Reports on the WFC3 website at:
http://www.stsci.edu/hst/wfc3/documents/ISRs/

Table E.12: Cycle 24 Calibration Programs

Proposal ID

Title

14529

UVIS Anneal

14530

UVIS Bowtie Monitor

14531

UVIS Daily Monitor A

14532

UVIS Daily Monitor B

14533

UVIS Daily Monitor C

14534

UVIS Unflashed Monitor

14535

UVIS Post-Flash Monitor

14536

UVIS CCD Gain Stability

14537

IR Dark Monitor

14538

IR Linearity Monitor

14539

IR Gain Monitor

14540

UVIS CTI Monitor (EPER)

14541

UVIS CTE Monitor (Star cluster)

14542

UVIS Traps with CI

14815

UVIS Contamination and Stability Monitor

14543

IR Grisms: Wavelength Calibration

14544

IR Grisms: Trace and Flux Calibration

14545

UVIS Grism Wavelength Calibration Stability

14546

UVIS Pixel-to-Pixel QE Variations Via Internal Flats

14547

UVIS Internal Flats

14548

IR Internal Flats

14549

CSM monitor Earth Flats

14550

WFC3 Astrometric Scale Monitoring

148681

Improved Precision, Wavelength Dependence of the IR Count Rate Non-Linearity

148701

IR Zeropoint Linearity

148711

Improving the CALSPEC model for GRW+70D5824

148781

UVIS Contamination Using Spatial Scans

148791

UVIS Sink Pixel Map Update

148801

UVIS CTE Model Re-characterization

148811

UVIS CTE Pixel-Based Model Evaluation

14882

UVIS Shutter Monitoring

14883

WFC3 UVIS & IR Photometry

1New programs this cycle; others are routine monitors.