1.1 New for Cycle 34
We have made the following updates to the WFC3 Instrument Handbook for this cycle:
- We updated information, plots, and references throughout the handbook based on the Instrument Science Reports (ISRs) released in 2025.
- We added Section 3.3.6, including Figure 3.8 and Figure 3.9, to compare select WFC3 bandpasses with Roman/WFI filters.
- We discussed recent WFC3/UVIS saturation analysis in Section 5.4.5, and replaced Figure 5.6 with the updated saturation map currently used in the calibration pipeline.
- We used new WFC3/UVIS gain data to update Section 5.4.6, including Table 5.3 and Figure 5.7.
- We improved scaling on the WFC3/IR pixel-to-pixel flats shown in Figure 5.28.
- We replaced Section 5.7.5 and Figure 5.29 to reflect updated WFC3/IR linearity correction calibration.
- We added a column for the cumulative throughput width for WFC3/UVIS filters and grism to Table 6.2.
- We reorganized Table 6.4 to show how WFC3/UVIS quad filters are grouped together in the filter wheel.
- We discussed issues with extrapolating WFC3/UVIS encircled energy curves for small apertures in Section 6.6.2.
- We added to Section 6.6.3 a brief discussion of fine-guidance jitter and its impact on the PSF.
- We clarified the significance of WFC3/UVIS extended pixel edge response (EPER) imaging in Section 6.7.2.
- We added references to new PSF extraction and modeling tutorials to Section 6.11.4.
- We added a column for the cumulative throughput width for WFC3/IR filters and grisms to Table 7.2.
- We calculated JWST/NIRCam limiting magnitudes and added them to Table 7.10.
- We updated Section 7.9.6 and Figure 7.15 to encompass the latest WFC3/IR blob analysis.
- We added new Cycle 34 guidance regarding grism direct images to Section 8.3.
- We discussed in Section 8.5 previous, current, and upcoming software tools for grism spectral extraction and calibration, and also added details about spectral dispersion from off-frame sources.
- We updated Section 10.2, Section 10.3, and Section 10.4 to reflect changes in guidestar acquisition, overheads, and orbit times under reduced gyro mode (RGM).
- We reviewed new analyses of the temporal evolution of WFC3/UVIS and WFC3/IR geometric distortion in Appendix B.1.
- The following changes have been made to Appendix E:
- We added the Cycle 33 calibration plan and time span to Table E.1 (Section E.1).
- We added a summary of the WFC3 calibration plan for the current Cycle in Section E.20.
- We added the Cycle 33 calibration plan and time span to Table E.1 (Section E.1).
-
WFC3 Instrument Handbook
- • Acknowledgments
- Chapter 1: Introduction to WFC3
- Chapter 2: WFC3 Instrument Description
- Chapter 3: Choosing the Optimum HST Instrument
- Chapter 4: Designing a Phase I WFC3 Proposal
- Chapter 5: WFC3 Detector Characteristics and Performance
-
Chapter 6: UVIS Imaging with WFC3
- • 6.1 WFC3 UVIS Imaging
- • 6.2 Specifying a UVIS Observation
- • 6.3 UVIS Channel Characteristics
- • 6.4 UVIS Field Geometry
- • 6.5 UVIS Spectral Elements
- • 6.6 UVIS Optical Performance
- • 6.7 UVIS Exposure and Readout
- • 6.8 UVIS Sensitivity
- • 6.9 Charge Transfer Efficiency
- • 6.10 Other Considerations for UVIS Imaging
- • 6.11 UVIS Observing Strategies
- Chapter 7: IR Imaging with WFC3
- Chapter 8: Slitless Spectroscopy with WFC3
-
Chapter 9: WFC3 Exposure-Time Calculation
- • 9.1 Overview
- • 9.2 The WFC3 Exposure Time Calculator - ETC
- • 9.3 Calculating Sensitivities from Tabulated Data
- • 9.4 Count Rates: Imaging
- • 9.5 Count Rates: Slitless Spectroscopy
- • 9.6 Estimating Exposure Times
- • 9.7 Sky Background
- • 9.8 Interstellar Extinction
- • 9.9 Exposure-Time Calculation Examples
- Chapter 10: Overheads and Orbit Time Determinations
-
Appendix A: WFC3 Filter Throughputs
- • A.1 Introduction
-
A.2 Throughputs and Signal-to-Noise Ratio Data
- • UVIS F200LP
- • UVIS F218W
- • UVIS F225W
- • UVIS F275W
- • UVIS F280N
- • UVIS F300X
- • UVIS F336W
- • UVIS F343N
- • UVIS F350LP
- • UVIS F373N
- • UVIS F390M
- • UVIS F390W
- • UVIS F395N
- • UVIS F410M
- • UVIS F438W
- • UVIS F467M
- • UVIS F469N
- • UVIS F475W
- • UVIS F475X
- • UVIS F487N
- • UVIS F502N
- • UVIS F547M
- • UVIS F555W
- • UVIS F600LP
- • UVIS F606W
- • UVIS F621M
- • UVIS F625W
- • UVIS F631N
- • UVIS F645N
- • UVIS F656N
- • UVIS F657N
- • UVIS F658N
- • UVIS F665N
- • UVIS F673N
- • UVIS F680N
- • UVIS F689M
- • UVIS F763M
- • UVIS F775W
- • UVIS F814W
- • UVIS F845M
- • UVIS F850LP
- • UVIS F953N
- • UVIS FQ232N
- • UVIS FQ243N
- • UVIS FQ378N
- • UVIS FQ387N
- • UVIS FQ422M
- • UVIS FQ436N
- • UVIS FQ437N
- • UVIS FQ492N
- • UVIS FQ508N
- • UVIS FQ575N
- • UVIS FQ619N
- • UVIS FQ634N
- • UVIS FQ672N
- • UVIS FQ674N
- • UVIS FQ727N
- • UVIS FQ750N
- • UVIS FQ889N
- • UVIS FQ906N
- • UVIS FQ924N
- • UVIS FQ937N
- • IR F098M
- • IR F105W
- • IR F110W
- • IR F125W
- • IR F126N
- • IR F127M
- • IR F128N
- • IR F130N
- • IR F132N
- • IR F139M
- • IR F140W
- • IR F153M
- • IR F160W
- • IR F164N
- • IR F167N
- Appendix B: Geometric Distortion
- Appendix C: Dithering and Mosaicking
- Appendix D: Bright-Object Constraints and Image Persistence
-
Appendix E: Reduction and Calibration of WFC3 Data
- • E.1 Overview
- • E.2 The STScI Reduction and Calibration Pipeline
- • E.3 The SMOV Calibration Plan
- • E.4 The Cycle 17 Calibration Plan
- • E.5 The Cycle 18 Calibration Plan
- • E.6 The Cycle 19 Calibration Plan
- • E.7 The Cycle 20 Calibration Plan
- • E.8 The Cycle 21 Calibration Plan
- • E.9 The Cycle 22 Calibration Plan
- • E.10 The Cycle 23 Calibration Plan
- • E.11 The Cycle 24 Calibration Plan
- • E.12 The Cycle 25 Calibration Plan
- • E.13 The Cycle 26 Calibration Plan
- • E.14 The Cycle 27 Calibration Plan
- • E.15 The Cycle 28 Calibration Plan
- • E.16 The Cycle 29 Calibration Plan
- • E.17 The Cycle 30 Calibration Plan
- • E.18 The Cycle 31 Calibration Plan
- • E.19 The Cycle 32 Calibration Plan
- • E.20 The Cycle 33 Calibration Plan
- • Glossary